Sears Kenmore Thermal Cut-Out

1996 Sears Kenmore Dryer made by Whirlpool(Model#11066912690): Not Heating at all. I found the thermal cut-out was out. This is caused by a restricted vent exhaust outlet, and inside the dryer was lots of excessive lint build up. Cleaned all the lint out, Installed a new thermal cut-off, Part#279769. The consumer will clean out their long exhaust vent.