I went out to see why this refrigerator wasn’t cooling. I found that the condenser fan motor, that’s located in the very back of the refrigerator, wasn’t running and blowing air. It had stopped running and I was getting 120 volts to it.

Also due to the condenser fan motor not running it overheated the compressor start relay and made that go bad too. So I replaced both parts and it worked great!

Here’s the condenser fan motor for this model:
WR60X10220 Condenser Fan Motor
WR60X10220 Condenser Fan Motor

Here’s the compressor start relay for this model:
WR07X10055 Relay Ptcr
WR07X10055 Compressor Start Relay